Dual Chamber Helium Bombing System ATLAS Leak Test Process Controller UN-250VH Dry Piston Vacuum Pump

Our Dual Chamber Helium Bombing System features two ASME helium pressure chambers made of stainless steel, removable lids,  and swing clamps for easy access when loading your test products. Bombing chambers are leak and pressure tested for full vacuum and operating pressures up to 100 PSI. 


System is controlled using our ATLAS Leak Test Process Controller and includes a dry vacuum pump rated at 3.5 CFM, 15 Torr or 29 inHg ultimate pressure. Mounted on a mobile cart, the system includes all the necessary vacuum hoses and connections between chambers and pump.

  • Two 10" X10" Leak Test ASME Pressure Bombing Chambers (100 PSI)
  • ATLAS Leak Test Process Controller - a flexible controller for helium charging, evacuation, airproof testing, and decay testing of products. Features include: 
    • Ethernet interface and remote control (RS232)
    • Enter test ID data manually or via bar code
    • Test summary log or live data stream to CSV file
    • Retrieve data by SD card or Ethernet connection
    • Data storage capacity of over 5 million test results via an internal 8GB SD card
Chamber Material:
304 stainless steel
Chamber Finish:
Electropolish
Chamber Dimensions:
9.5" ID x 9.5" IH,  17-1/4" OH
Chamber Lid:
Fully removable with handle and full size opening. Swing clamped lid suitable for both full vacuum or pressure
Operating Pressure:
Chambers are leak and pressure tested for full vacuum and operating pressures to 100 psi
Chamber Ports:
  • 1/4" port on cross with manual valve adapted to NW 25 vacuum flange for evacuation
  • 1/4" port on cross for helium fill manual valve to connect to regulated helium supply
  • 1/4" port on cross for manual valve for venting chamber
  • Spare 3/4" NPT port on chamber bottom, blanked off, safety overpressure relief valve installed and set to 100 PSI
Gauge: 
Manual analog 2.5" face pressure gauge from 0-30 inHG and 0-100 psi
Vacuum Pump:
LACO UN-250VH Dry Vacuum Pump (3.5 CFM)
Controller:
ATLAS Leak Test Process Controller
Configuration: 
Mobile Cart