AURA Compact — Left Side View AURA Compact — Right Side View

The AURA Compact Mass Flow Leak Tester is a powerful, reliable and cost-effective solution for your air leak testing requirements.

  • Test Method: Direct Mass flow
  • Channels: One
  • Valves: Low flow (small to medium parts)
  • Regulator: Single manual regulator
  • Test Pressure: 0-50 psig
  • Mass Flow Range: 0-20 scc/m

COMMUNICATION & DATA LOGGING

  • Data storage capacity of over 5 million test results via internal 8GB SD card
  • Enter test ID data manually or via optional bar code reader
  • Test summary log to .csv file
  • Retrieve data by SD card or RS232 connection
  • Ethernet interface

AVAILABLE ACCESSORIES

  • Bar code reader
Operator Interface Display:
7.0″ color touchscreen
Overall Dimensions:
9″ H x 12″ W x 12″ D (23 cm x 30.5 cm x 30.5 cm)
Leak Rate Sensitivity (part size, time, pressure dependent)
< 0.1 sccm
Pressure Sensor Resolution (decay mode, 15 psig):
24 bit A/D, 0.00001 psi resolution
Test Pressure Range:
Vacuum to 100 psig
Available Test Channels:
1
Available Test Methods (one method per configuration):
Pressure & Vacuum Decay, Differential Pressure Decay, Mass Flow (Direct & Differential)
Communication Interface:
Serial/RS232/Ethernet
Discrete Interface:
Remote control, clamp output
Ticket Printer:Not available


No accessories available.

Product Brochures

AURA Compact Air Leak Tester

Reference Materials

Presentation: Succeeding with Production Air Leak Testing Methods