An aerospace industry customer required a high vacuum system to test and validate the integrity of their imaging system components under extreme pressure and temperature conditions.

Our Solution

We configured a system using our standard 36″ diameter by 40″ deep vacuum chamber utilizing a cast aluminum platen with an embedded LN2 manifold and electrical heating elements to achieve the target temperature ranges. A cylindrical thermal shroud with LN2 cooling on a separate cooling zone was also included. This FST system also included as standard or ISO 160, 6″ diameter door viewport with internal LED lighting. Vacuum pumping system included a dry roughing pump and upgraded high pumping speed cryopump high vacuum pump package.

System is fully integrated on a ruggedized mobile frame and testing is controlled entirely using our versatile HVC-3500 Thermal Vacuum Controller.

  • System Platform: 36″ DIA x 40″ L cylindrical horizontal vacuum chamber made of 304 stainless steel and a #4 grain polish on the inside for vacuum to 10-7 torr
  • Platen: Internal cast aluminum platen, approximately 24″ W x 38″ L with internal thermal channeling and mounting points laid out on a 4″ grid
  • Shroud: Internal shroud – 304 SS pillow-plated shroud, offset 1″ from chamber wall
  • Process Controller: HVC-3500 Thermal Vacuum Controller with 7″ color touch screen, 2 analog inputs, 10 digital inputs, and 6 relay outputs
  • Thermal Zones: Zone 1 Platen includes LN2 and electrical heat for heating and cooling, Zone 2 includes LN2 cooling of shroud.
  • Pump package: Dry roughing pump and cryopump high vacuum pump
  • System Enclosure: Ruggedized frame w/heavy-duty casters and electrical panel enclosure

HVC-3500 Controller Features

  • 20 customizable recipes
  • Full system integration
  • Automated vacuum & temperature control
  • Data logging
  • Remote access
Chamber Dimensions: 36″ DIA x 40″ Cylindrical Length plus dished ends
Chamber: Series HH 36″ X 40″ vacuum chamber
Approximate Volume: 40,700 (in³)
Vacuum Rating: 1 x 10-6 Torr
Temperature Rating: Platen: -150 °C to 200 °C
Shroud: -150 °C
Thermal Management: Cooling: LN2 manifold
Heating: Electric heaters
Chamber/Door Material: 304 stainless steel
Finish: #4 grain machine polish interior and a glass bead blast exterior
Ports: NW50, NW40, NW25, NW16,
ISO200, ISO160, ISO100, ISO63
Lighting: LED lights, mounted on inside of door
Controller: HVC-3500 thermal vacuum controller
Pumping System: Dry scroll roughing pump and two-stage cold head cryopump package

HVC-3500 Thermal Vacuum Controller

For ultimate flexibility and control of your vacuum system, the feature-packed HVC-3500 Thermal Vacuum Controller provides automated vacuum and temperature control, customizable software, and adjustable test recipes for your unique and complex vacuum processes. The HVC-3500 is ideal for any vacuum system requiring heating or cooling, and integrates vacuum gauges and valves for either automated mode or interlocked manual mode operation.