Custom Solution | Non-Helium (Refrigerant) Leak Test System for Refrigerant Control Valves

SKU:

X-029680

A customer required a custom leak test system using R410a to leak test refrigerant control valves. System requirements included:

  • Leak test refrigerant-charged control valves using the refrigerant (R410a) as the tracer gas
  • High production demand
  • Prevent valve components and residues from interfering with leak measurement signal
  • Method of calibrating the system

We engineered a custom, dual-chamber leak test system using RGA refrigerant as the tracer gas. Multiple leak test chambers accommodated batch testing and increased throughput with a leak test manifold calibrated for multiple calibrations.

  • Dual-chamber RGA-based refrigerant leak test system
  • Batch testing configuration for higher throughput
  • Multi-point calibrated leak manifold for R410a validation
  • Hard vacuum measurement method for refrigerant detection
  • Designed to minimize signal interference from valve residues
Application: Leak testing A/C parts
Industry: Automotive & Transportation
Production Volume: Medium to high
Tracer gas: RGA
Controller System: Custom PLC
Leak Test Method: Hard vacuum
Leak rate: 1 x 10-7 atmcc/sec R410a
Throughput: Approximately 2 valves per minute
Configuration: Portable station

 