A manufacturer came to us needing a fully automated leak test system for airbag inflators. The customer required fully automatic loading and unloading of multiple part models and sizes, a low leak rate reject limit, and a high throughput rate.
LACO delivered a fully automated, high volume production leak test system for gas-filled airbag inflators using the helium hard vacuum leak test method. Featuring multiple chambers and a robotic pick-and-place material handling system, this leak test system automated part sorting and marking, feed and exit conveyors, and universal grippers for different part models.
| Leak Test Method: | Helium hard vacuum chamber, pre-filled part |
| Leak Rate: | 1 x 10-8 atmcc/sec |
| Throughput: | 1 part every 5 seconds |
| Test Pressure: | 300 to 450 bars |
| Tracer gas: | Helium 3% |
| Test Chambers: | 2 chambers, each chamber has two individual cavities |
| Automated Load/Unload time: | less than 5 seconds |