icon-menu-x-close

Custom Solution | Hard Vacuum Leak Test System for Testing of Prismatic Battery Cells

SKU:

X-1P32364

A worldwide leader in automated assembly and testing solutions required a system for leak testing prismatic battery cells. The application demanded multiple test chambers, integrated automation, and consistent high-throughput performance.

LACO custom engineered an automated leak test system with 4 test chambers that can be run simultaneously. Each chamber includes a dedicated roughing pump and a hydraulic system for closing and sealing the chamber. The system utilizes the hard vacuum helium test method with a helium mass spectrometer leak detector for high sensitivity, test reliability, uptime, and fast cycle times. The system incorporates a gross leak test prior to the helium test.

  • Four independent leak test chambers operating in parallel
  • Hydraulic system for controlled chamber closing, sealing, and opening
  • Dedicated roughing pump for each chamber to support consistent performance
  • Hard vacuum helium leak testing with mass spectrometer detection
  • Integrated gross leak test prior to helium testing
Industry Automotive & Transportation
Application EV Batteries & Components
Leak Test Method Helium Hard Vacuum
System Weight 1500 lbs.
System Dimensions 60″ W x 80.5″ H x 61.2″ D
Electrical Requirements 240 VAC | 40 Amps | 60 Hz | Single phase
Air Supply Requirements 80-120 psi
Process Gas Supply 3 bar absolute minimum