icon-menu-x-close

Custom Solution | Dual Chamber Helium Bombing System

SKU:

X-1P30431

A manufacturer of turnkey parts assemblies required a custom, automatic PLC-controlled dual chamber helium bombing system for leak testing of customer components.

  • Two 304 stainless steel bombing chambers with electropolished finish with fully removable, clamped lid suitable for both vacuum and pressure
  • ASME approved for 110 psi
  • ATLAS Tracer Gas Charge System and Leak Test Process Controller for automated control of bombing process for both helium bombing chambers with multiple user-defined recipe parameters
Chamber Material: 304 stainless steel
Lid Material: 304 stainless steel
Dimensions: 10″ OD x 10″ H (overall height 17 1/4″)
Lid Configuration: Fully removable with handle and full size opening. Swing clamped lid suitable for both full vacuum or pressure
Vacuum Connection: 1/4″ vacuum port with manual valve adapted to NW 25 vacuum flange (NW 16 available upon request)
Helium Connection: 1/4″ port with manual valve and push connect fitting for 1/4″ plastic tubing from regulated helium supply
Vent Port: 1/4″ NPT vent and safety pressure relief valve set to 75 psig
Finish: Electropolish interior and exterior
Operating Pressure: Chamber is leak and pressure tested for full vacuum and operating pressures to 100 psi
Gauge: Manual analog 2.5″ face pressure gauge from 0-30 inHG and 0-100 psi
Pumping System: W2V40 LACO Two stage Oil Sealed Rotary Vane High Vacuum Pump 14 cfm
Controller: ATLAS Tracer Gas Charge System and Leak Test Process Controller

 

ATLAS Leak Test Process Controller – Charge Only, Standard Pressure

This ATLAS Leak Test Process Controller configuration is ideal for users who need either automated helium bombing charge control or automated pre-fill of their parts before leak testing. The ATLAS Controller allows for fully automated part charging process, up to...