A manufacturer of turnkey parts assemblies required a custom, automatic PLC-controlled dual chamber helium bombing system for leak testing of customer components.
| Chamber Material: | 304 stainless steel |
| Lid Material: | 304 stainless steel |
| Dimensions: | 10″ OD x 10″ H (overall height 17 1/4″) |
| Lid Configuration: | Fully removable with handle and full size opening. Swing clamped lid suitable for both full vacuum or pressure |
| Vacuum Connection: | 1/4″ vacuum port with manual valve adapted to NW 25 vacuum flange (NW 16 available upon request) |
| Helium Connection: | 1/4″ port with manual valve and push connect fitting for 1/4″ plastic tubing from regulated helium supply |
| Vent Port: | 1/4″ NPT vent and safety pressure relief valve set to 75 psig |
| Finish: | Electropolish interior and exterior |
| Operating Pressure: | Chamber is leak and pressure tested for full vacuum and operating pressures to 100 psi |
| Gauge: | Manual analog 2.5″ face pressure gauge from 0-30 inHG and 0-100 psi |
| Pumping System: | W2V40 LACO Two stage Oil Sealed Rotary Vane High Vacuum Pump 14 cfm |
| Controller: | ATLAS Tracer Gas Charge System and Leak Test Process Controller |
This ATLAS Leak Test Process Controller configuration is ideal for users who need either automated helium bombing charge control or automated pre-fill of their parts before leak testing. The ATLAS Controller allows for fully automated part charging process, up to...
Product Brochures
Manuals/User Guides
Application Notes