Custom Solution | Dual Chamber Helium Bombing System for Hermetically Sealed Parts

SKU:

X-1P25764

A company specializing in the design and manufacture of electro-mechanical hermetically sealed relays, time delay devices and mating sockets required a helium bombing system. Using our standard 10″ X 10″ Bombing Chamber, we engineered a custom tabletop bombing system integrating our ATLAS™ Leak Test Process Controller for automated control over both bombing chambers.

  • 10″ X 10″ Bombing Chamber features stainless steel construction, completely removable lid with large opening, 3 – 1/4″ NPT ports on cross-for supply, evacuation and vent, and a 0-30 inHg to 100 psi compound gauge. The chamber operates up to 100 psi, and is ASME stamped and approved for 110 psi.
  • ATLAS™ Leak Test Process Controller with helium charging with part evacuation, air fill, and helium fill options and up to 100 customized test recipes (see product link for full specifications)
  • System components shipped for on-site assembly on customer workstation
Chamber Material: 304 stainless steel
Lid Material: 304 stainless steel
Finish: Electropolished interior and exterior
Chamber Dimensions: 10″ DIA x 10″ H
Lid: Fully removable with handle and full size opening. Swing clamped lid suitable for both full vacuum or pressure
Operating Pressure: Chamber is leak and pressure tested for full vacuum and operating pressures to 100 psi
Ports: 1/4″ port on cross with manual valve adapted to NW 25 vacuum flange for evacuation, 1/4″ port on cross for helium fill manual valve to connect to regulated helium supply, 1/4″ port on cross for manual valve for venting chamber, spare 3/4″ NPT port on chamber bottom, blanked off, safety overpressure relief valve installed and set to 100 psi
Gauge: Manual analog 2.5″ face pressure gauge from 0-30 inHG and 0-100 psi
Controller: ATLAS™ Leak Test Process Controller
Pumping System: LACO Model UN-200VH dry vacuum pump, 4.4 CFM, 15 Torr

 

10″ DIA x 10″ H Manual Helium Bombing Chamber

The 10″ DIA X 10″ H vertical manual helium bombing chamber is designed for pressurizing medium to large size parts for helium bombing applications. LACO’s Manual Gas Charge Manifold provides all features to evac, fill and vent the chamber. The chamber is electropolished 304 stainless steel construction and has a removable clamped lid. The chamber is ASME certified and operates up to 100 psig and full vacuum and is helium leak tested.

ATLAS Leak Test Process Controller – Charge Only, Standard Pressure

This ATLAS Leak Test Process Controller configuration is ideal for users who need either automated helium bombing charge control or automated pre-fill of their parts before leak testing. The ATLAS Controller allows for fully automated part charging process, up to...